Multiple hardware sensors status shows as unknown and absent hardware's status shows warning on HPE Gen 10 servers

Lear 2024-09-24 10:00:00
Categories: Tags:

Multiple hardware sensors status shows as unknown and absent hardware’s status shows warning on HPE Gen 10 servers

Symptoms:


Cause

HPE Gen10 servers, iLO 5 firmware 1.30 has new sensors which cause unspecified status for I/O Modules . For more information, see the HPE Customer Advisory

Resolution

The fix implemented is to ignore sensor warnings on iLO firmware prior to version 1.40.

To implement this fix upgrade to patch as below
ESXi 6.5 P04 - patch esxi650-201912002. For more information see release notes
ESXi 6.7 P01 - patch esxi670-201912001. For more information see release notes

To download the patch go to Customer Connect

Workaround:
To workaround this issue downgrade the iLO5 firmware to 1.20.

Additional Information

Refer to VMware KB to correlate patch and build numbers
There are some additional improvements in HPE iLO5 firmware 1.40. For more information see HPE advisory

Impact/Risks:
Requires a ESXi host reboot.